——Provide from Home Mining to Large-scale Mining Solutions
Multiple models of Antminer, Whatsminer and Avalon
21kW@38°C/24kW@35°C/28kW@33°C
Outsize | 1185(L)*530(W)*760(H)mm |
Insize | 912(L)*404(W)*355(H)mm |
G.W. | 110kg |
Coolant Volume | 200L |
Cycle Mode | Single Loop |
Input Voltage | Single-Phase 200-240V 50/60Hz |
Power Usage (Max) | 800-1100W |
Noise | 45dB(A)@10m |
Flow | 90L/min |
Qty of Miner(s) | 6*S19/S21
8*M50/M60 |
PDU | Single-phase: 220V 125A 6C19
Three-phase: 380V 63A 6C19 |
Outer Size | 1680(L)*400(W)*1015(H)mm |
Input Voltage | Single-Phase 200-240V 50/60Hz |
Power Usage (Max) | 10-1400W(220V 50Hz) |
G.W. | 110kg |
Cooling Capacity | 24kW@35℃ |
Fluid In / Out | 63-53°C |
Electrical Interface | C14 *1 |
Fan Type | EC Fan |
Noise | 65dB(A)@10m (MAX) |
What is the connection method of the C2 power supply?
The mining rigs in C2 is directly connected to the power supply or PDU at home, and the tank and dry cooler are connected through standard C13 connectors.
What is the operating logic of the C2 fan? Can it be adjusted automatically?
Our C2 uses an EC fan to adjust the speed according to the temperature of the oil entering the tank (dry cooler oil temperature).There are 2 modes to choose (the mode is changed by a button inside the waterproof junction box outside the dry cooler).Press the button down is HEATING mode (waste heat utilization mode) 41.3℃ to start the dry cooler, 49.7℃ to maximize the dry cooler speed. Press the button up is NORMAL mode (normal operation mode), 20.5℃ to start the dry cooler, 28.9℃ to maximize the dry cooler speed.
How long is the pipeline for the C2 tank?
We provide two 5m pipeline as standard, and we also support customizing other lengths for a fee.
Will the tank automatically power on after a power outage?
Following a power outage, the tank is unable to initiate an automatic startup and necessitates manual activation by clicking on the screen.
How noisy is the C2 system?
The C2 tank noise about 45dB, the dry cooler will reach 68dB(A) 10m at full speed.
What is the size of the C2 pump?
With an input voltage of 220V 50Hz, the pump has a power of 150W, and the maximum flow rate for circulating the Coolant is 36L/min, with a maximum head of 10m.
What is the C2 pipeline connector size?
C2 pipeline connector size is DN25 (External thread diameter Pipeline diameter 32mm).
What should you do if there is high-frequency noise in the junction box when the fan is running at full speed?
In general, this issue might arise due to the loose fastening of screws on the internal PCB board of the junction box. You should dismantle the junction box and tighten the screws securely. If the screws cannot be tightened, you can try to replace the screws or add gaskets to tighten the screws (M3 screws and gaskets). If the problem persists, you can try to add gaskets (preferably rubber anti-vibration pads) at the bottom of the dry cooler to raise the fan to prevent noise caused by contact between the bottom of the dry cooler and the ground.
How to properly unload oil to avoid waste?
First, pump the oil out using the oil filling pump in the accessories. At the same time, there is an oil discharge port in the middle of the liquid separator plate at the bottom of the tank. After removing the screw, plug the oil filling pump in to clean up the liquid at the bottom of the liquid separator plate.
How does the oil filling pump work in accessories?
Instructions1. Connect the pump to the inlet and outlet pipes: Ensure a tight seal between the pipes and the pump to prevent low pressure or leakage. The arrow on the pump head indicates the direction of the outlet.2. Put the water inlet pipe below the coolant level, and put the water outlet pipe in the corresponding storage coolant receptacle.3. Connect the pump to the pump power adapter and then power on.
What is the material of C2 kit?
The material of C2 tank is cold-rolled steel , the dry cooler is copper and aluminum fins.
If the C2 pump stops or reports an error, what will happen?
If the pump stops working, a “Pump Error” prompt will appear on our Tank’s display screen, accompanied by an alarm sound. If this situation is not addressed, the temperature of the coolant will continue to rise due to the inability to dissipate heat. Eventually, this will trigger the temperature protection mechanism of the mining rigs, causing them to stop operating automatically.
For most areas, the liquid cooling equipment will be shipped to you via sea freight. Ports and receiving points in different regions will incur different shipping charges. It is recommended that you contact customer service to confirm address details and calculate shipping costs before placing an order.
Please send us your RFQ to get your exclusive sales manager assistance.
Options | C6 Tank, C6 Tank + Dry cooler, C6 Tank + Dry cooler + Coolant |
---|
There are no question found.
Week | Month | 3 Months | Year |
---|
——Provide from Home Mining to Large-scale Mining Solutions
Multiple models of Antminer, Whatsminer and Avalon
21kW@38°C/24kW@35°C/28kW@33°C
Outsize | 1185(L)*530(W)*760(H)mm |
Insize | 912(L)*404(W)*355(H)mm |
G.W. | 110kg |
Coolant Volume | 200L |
Cycle Mode | Single Loop |
Input Voltage | Single-Phase 200-240V 50/60Hz |
Power Usage (Max) | 800-1100W |
Noise | 45dB(A)@10m |
Flow | 90L/min |
Qty of Miner(s) | 6*S19/S21
8*M50/M60 |
PDU | Single-phase: 220V 125A 6C19
Three-phase: 380V 63A 6C19 |
Outer Size | 1680(L)*400(W)*1015(H)mm |
Input Voltage | Single-Phase 200-240V 50/60Hz |
Power Usage (Max) | 10-1400W(220V 50Hz) |
G.W. | 110kg |
Cooling Capacity | 24kW@35℃ |
Fluid In / Out | 63-53°C |
Electrical Interface | C14 *1 |
Fan Type | EC Fan |
Noise | 65dB(A)@10m (MAX) |
What is the connection method of the C2 power supply?
The mining rigs in C2 is directly connected to the power supply or PDU at home, and the tank and dry cooler are connected through standard C13 connectors.
What is the operating logic of the C2 fan? Can it be adjusted automatically?
Our C2 uses an EC fan to adjust the speed according to the temperature of the oil entering the tank (dry cooler oil temperature).There are 2 modes to choose (the mode is changed by a button inside the waterproof junction box outside the dry cooler).Press the button down is HEATING mode (waste heat utilization mode) 41.3℃ to start the dry cooler, 49.7℃ to maximize the dry cooler speed. Press the button up is NORMAL mode (normal operation mode), 20.5℃ to start the dry cooler, 28.9℃ to maximize the dry cooler speed.
How long is the pipeline for the C2 tank?
We provide two 5m pipeline as standard, and we also support customizing other lengths for a fee.
Will the tank automatically power on after a power outage?
Following a power outage, the tank is unable to initiate an automatic startup and necessitates manual activation by clicking on the screen.
How noisy is the C2 system?
The C2 tank noise about 45dB, the dry cooler will reach 68dB(A) 10m at full speed.
What is the size of the C2 pump?
With an input voltage of 220V 50Hz, the pump has a power of 150W, and the maximum flow rate for circulating the Coolant is 36L/min, with a maximum head of 10m.
What is the C2 pipeline connector size?
C2 pipeline connector size is DN25 (External thread diameter Pipeline diameter 32mm).
What should you do if there is high-frequency noise in the junction box when the fan is running at full speed?
In general, this issue might arise due to the loose fastening of screws on the internal PCB board of the junction box. You should dismantle the junction box and tighten the screws securely. If the screws cannot be tightened, you can try to replace the screws or add gaskets to tighten the screws (M3 screws and gaskets). If the problem persists, you can try to add gaskets (preferably rubber anti-vibration pads) at the bottom of the dry cooler to raise the fan to prevent noise caused by contact between the bottom of the dry cooler and the ground.
How to properly unload oil to avoid waste?
First, pump the oil out using the oil filling pump in the accessories. At the same time, there is an oil discharge port in the middle of the liquid separator plate at the bottom of the tank. After removing the screw, plug the oil filling pump in to clean up the liquid at the bottom of the liquid separator plate.
How does the oil filling pump work in accessories?
Instructions1. Connect the pump to the inlet and outlet pipes: Ensure a tight seal between the pipes and the pump to prevent low pressure or leakage. The arrow on the pump head indicates the direction of the outlet.2. Put the water inlet pipe below the coolant level, and put the water outlet pipe in the corresponding storage coolant receptacle.3. Connect the pump to the pump power adapter and then power on.
What is the material of C2 kit?
The material of C2 tank is cold-rolled steel , the dry cooler is copper and aluminum fins.
If the C2 pump stops or reports an error, what will happen?
If the pump stops working, a “Pump Error” prompt will appear on our Tank’s display screen, accompanied by an alarm sound. If this situation is not addressed, the temperature of the coolant will continue to rise due to the inability to dissipate heat. Eventually, this will trigger the temperature protection mechanism of the mining rigs, causing them to stop operating automatically.
For most areas, the liquid cooling equipment will be shipped to you via sea freight. Ports and receiving points in different regions will incur different shipping charges. It is recommended that you contact customer service to confirm address details and calculate shipping costs before placing an order.
Please send us your RFQ to get your exclusive sales manager assistance.
Model | Coin | Hashrate | Power | Efficiency | Earning 24H | Daily Electricity Cost | ShutDown Price | Miner Price | PayBack (Days) |
Net Profit Per Day |
|
---|---|---|---|---|---|---|---|---|---|---|---|
Aethir Edge ATH Miner
Delivery Time:
In-stock
|
|
100
ATH
|
18
W
|
N/A
|
$8.00
|
-$-0.02
|
$ |
$1,299 12.99 $/ATH |
163 |
$7.98
|
All orders are dispatched in batches, with machines shipped within 3-7 days from stock; bulk orders may require an additional day or two. We aim to ship promptly via DHL Express, UPS, Fedex, or TNT after confirming full payment (wire transfers may take 3-7 business days, while cryptocurrency payments are usually verified within a few hours to 1 business day).
International shipping generally takes 5-8 business days, and DDP shipping can take 8-10 days.
*Please note that all sales are final and non-refundable.
Accepted payment methods:
1. Bank transfer/Wire transfer (T/T)
2. USDT
3. For other methods, please consult our sales expert.
*All machine price is fluctuating based on the crypto market so our quotes are only valid on the day of publication.*
We primarily ship via DHL Express, UPS, or FedEx. For certain countries, we offer DDP (Delivery Duty Paid) shipping, meaning clients do not incur any duties or customs charges.
DDP Shipping Countries: United States, Germany, Russia, Dubai, United Kingdom, France, Belgium, Luxembourg, Netherlands, Denmark, Czech Republic, Poland, Austria, Ireland, Portugal, Sweden, Spain, Vietnam, Thailand, Malaysia, as well as Indonesia, the Philippines, Canada, and the entire European Union (note: some countries require a minimum order of 30kg).
To request DDP shipping, please contact us at [email protected]
For non-DDP countries or standard shipping, we can help reduce your tax by issuing a lower invoice.
*Our products exclude all value-added taxes and customs duties, and you will be responsible for paying any applicable taxes and duties according to your country’s laws. Additionally, if any miner needs to be returned to Hong Kong, the client will cover the extra shipping costs.
We offer:
1. Marketing Photos and Video Package
2. Competitive Wholesale Prices
3. Support Dropshipping Service
4. Technical Support
All orders are dispatched in batches, with machines shipped within 3-7 days from stock; bulk orders may require an additional day or two. We aim to ship promptly via DHL Express, UPS, Fedex, or TNT after confirming full payment (wire transfers may take 3-7 business days, while cryptocurrency payments are usually verified within a few hours to 1 business day).
International shipping generally takes 5-8 business days, and DDP shipping can take 8-10 days.
*Please note that all sales are final and non-refundable.
Accepted payment methods:
1. Bank transfer/Wire transfer (T/T)
2. USDT
3. For other methods, please consult our sales expert.
*All machine price is fluctuating based on the crypto market so our quotes are only valid on the day of publication.*
We primarily ship via DHL Express, UPS, or FedEx. For certain countries, we offer DDP (Delivery Duty Paid) shipping, meaning clients do not incur any duties or customs charges.
DDP Shipping Countries: United States, Germany, Russia, Dubai, United Kingdom, France, Belgium, Luxembourg, Netherlands, Denmark, Czech Republic, Poland, Austria, Ireland, Portugal, Sweden, Spain, Vietnam, Thailand, Malaysia, as well as Indonesia, the Philippines, Canada, and the entire European Union (note: some countries require a minimum order of 30kg).
To request DDP shipping, please contact us at [email protected]
For non-DDP countries or standard shipping, we can help reduce your tax by issuing a lower invoice.
*Our products exclude all value-added taxes and customs duties, and you will be responsible for paying any applicable taxes and duties according to your country’s laws. Additionally, if any miner needs to be returned to Hong Kong, the client will cover the extra shipping costs.
We offer:
1. Marketing Photos and Video Package
2. Competitive Wholesale Prices
3. Support Dropshipping Service
4. Technical Support
As of Dec 21, 2024, considering an electricity cost of $0.04/KWh, the Immersion Cooling C6 has the following profit calculations:
Select the case’s appropriate size, preferred colour, and preferred style to go with the decor of your space. Keep your Immersion Cooling C6 on a protective frame, open all sides for adequate airflow and install fans for more ventilation. Ventilation is the most important thing for mining hardware to deliver better. To create a well-ventilated inside and out, install fans as per requirement and use foaming or wooden frames.
You must now connect your mining equipment to an electricity source. We are all aware that the primary need for cryptocurrency miners is energy. It is when you connect your miner to the power source that your miner gets the power to initiate. Connect your Immersion Cooling C6 to the internet connection, is interface for Immersion Cooling C6. Ensure it is connected to the internet.
There are two ways to get an IP address: you can choose any of the two options at your convenience. The first option is the DHCP address by logging into the home router and filling in all the details. The other option is to install some free mining software and grab the IP address from there. Once done, paste the IP address on a new webpage and enter the credentials, such as your username and password, to authorize it.
Entering a pool will improve your chances of receiving payments more frequently and consistently by rewarding you with small amounts of coin whenever all pool members complete an algorithm. A pool is a collection of cryptocurrency miners who cooperate and pool their hashing capacity to solve equations across the network. Once you have joined the pool, set it up per your mining requirements.
Multiple wallets, such as software or hardware wallets, are available online. Follow all the instructions on the official website of the crypto exchange or crypto wallet you choose. Then, you can use your wallet address as a method of payment to accept coins.
The next step is to set up your miner by filling in all the essential details in the interface that appears when you log in using the credentials provided. Fill in the details such as owner’s accounts, mining pool details, addresses, wallet addresses and other required fields.
Now that your Immersion Cooling C6 setup process is complete, you can start mining coins. Just be sure to launch the miner with a greater hash rate. Your Immersion Cooling C6 is now set up and running, and you can anticipate seeing a return on your investments.
Now that your setup is complete and you have started mining , it’s crucial to analyze how well it performs compared to your expenses and keep a keen eye on the working of your Immersion Cooling C6.
We’re excited to announce our partnership with Rabidming Trades! This collaboration will bring you the latest innovations in crypto mining, providing you with the best equipment and expert insights to stay ahead of the curve.
Geek Of All Trades is your go-to source for crypto mining expertise. Explore their YouTube channel for in-depth videos on ASIC, GPU, and FPGA mining, and gain the knowledge you need to thrive.
CoinGabbar is a cryptocurrency platform that offers a range of features and services, such as price tracking and market analysis tools.
The platform has news and blog sections with articles about the latest info and developments from the cryptocurrency world.
Request inventory & stock list Get the weekly Leedminer miner price list and inventory availability.
Shop by Coin
Shop by Algorithm
Shop by Brand
🔥 Featured Products
Shop by Algorithm
Featured Products
Only logged in customers who have purchased this product may leave a review.
Rating & Review
There are no reviews yet.